RA-150
High Volume, Remote, Refrigerated, Post Mix Juice System
The RA-150 potable water chiller can solve all your cold water problems. Due to its unique UltraChill™ technology, it can improve ice machine output, eliminate labor-intensive, pre-mix juice systems, and enhance soda and production. In fact it can do several of these things simultaneously.
Refrigeration System
The unique Ultrachill refrigeration system is powered by a per rod actually 1¾ horsepower, hermetically sealed, continuously running compressor. A hot gas bypass valve coupled with an externally equalized thermostatic expansion valve actually adjusts the Unit's horsepower to the load demands, and maintains a constant pressure in the Tri-axial evaporator. This results in the delivery of constant temperature (+/- 1/8F) by the RA-150.
Juice Systems
The RA-150 can be used to refrigerate and recirculate water through remote lines to dispense post-mix juice products. These systems utilize low cost, post-mix juice concentrates with chilled water from the RA-150 to produce chilled, quality juice drinks without the use of cold plates or other refrigeration. A complete system includes the RA-150, a bag-in-box rack, chilled water/juice concentrate line runs, and juice dispensers, and offers these advantages:
- Reduces Food Costs
Utilizes cost efficient bag-in-box, post mix
concentrate.
- Sanitary
Sealed system does not require sanitation.
- Saves Labor
No pre-mixing or clean up labor as required with pre-mix systems. Product is automatically mixed at the post-mix dispensing valve as needed.
- Less Waste
Cardboard bag-in-box cartons are recyclable resulting in less refuse than for pre-mix product or for individual portions.
- Multi Station Capability
One system can dispense several different juice products to multiple dispensing stations.
- Constant Temperature
Chilled water is continuously recirculated, rechilled and maintained within +/- 1/8F of desired temperature, usually 38 to 40 degrees F.
Mechanical Requirements
- Electrical
Dedicated circuit 230-208/60/1-30AMP
- Plumbing
¾" cold water supply
- Heat Rejection
16,000 BTU per hour maximum
- Ventilation
1500 CFM power exhaust minimum for air-cooled unit
Available Options
- Water pressure booster pump(s) for low water pressure applications
- Single or dual refrigeration / evaporator
configurations
|